2018 China New Design Standard Model Patient Monitor - AURORA-8S 8.4 inch semi-modular ambulance patient monitor optional for ambulance – Merry
2018 China New Design Standard Model Patient Monitor - AURORA-8S 8.4 inch semi-modular ambulance patient monitor optional for ambulance – Merry Detail:
AURORA-8S 8.4-inch semi-modular ambulance patient monitor optional for ambulance
Patient monitor
Product Detail:
◆Indication of incorrect manipulation and malfunction analysis
◆Patient info input management function
◆Multi-lead ECG waveforms display in phase
◆Large volume of tabular and graphic trends information storage and easy to recall
◆Capture dynamic waveforms
◆Up to 5 hours working capacity of built-in rechargeable lithium battery
◆Unique accessory management cabinet
◆Networking capacity
◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Accessories
Optional modular
Standard configuration |
|
Screen |
|
Display Type | 8″ color TFT LCD |
Resolution | 800×600 pixels |
Waveforms | Up to 7 |
ECG |
|
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *1.2 |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate range | 15-30bpm |
Calibration | ±1mv |
Accuracy | ±1bpm or ±1% (select the bigger data) |
NIBP |
|
Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
SPO2 |
|
Display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±3% (between 70%-100%) |
Pulse rate range | 20-300bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) |
|
Number of channels | 2 channels |
Measurement range | 0-50℃ |
Accuracy | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) |
|
Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
Optional configuration |
|
EtCO2-Plug & Play |
|
Measurement type | Side stream |
Measurement range | 0-10.0%; 0-76mmHg |
Accuracy | <5.0%, ±0.28kPa; ±2mmHg |
>5.0%, ±10% | |
2-IBP (optional) |
|
Measurement range | 10~300mmHg |
Number of channels | 1 or 2 channels |
Accuracy | ±1mmHg or ±2%, select bigger data |
Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
12 leads ECG (optional) |
|
Input | 3/5/10 wires ECG cable |
Lead section | I, II, III aVR, aVL, aVF, V(V1-V6) |
Heart rate range | 15-380bpm |
Calibration | ±1mv |
Product detail pictures:
Related Product Guide:
Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for 2018 China New Design Standard Model Patient Monitor - AURORA-8S 8.4 inch semi-modular ambulance patient monitor optional for ambulance – Merry, The product will supply to all over the world, such as: Algeria, Karachi, Haiti, With excellent products, high quality service and sincere attitude of service, we ensure customer satisfaction and help customers create value for mutual benefit and create a win-win situation. Welcome customers all over the world to contact us or visit our company. We will satisfy you with our professional service!
By Sara from Turkmenistan - 2017.08.28 16:02
Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
By Jean Ascher from Lithuania - 2018.12.22 12:52