AURORA-8S 8.4-inch semi-modular ambulance patient monitor optional for ambulance
Patient monitor
Product Detail:
◆Indication of incorrect manipulation and malfunction analysis
◆Patient info input management function
◆Multi-lead ECG waveforms display in phase
◆Large volume of tabular and graphic trends information storage and easy to recall
◆Capture dynamic waveforms
◆Up to 5 hours working capacity of built-in rechargeable lithium battery
◆Unique accessory management cabinet
◆Networking capacity
◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Accessories
Optional modular
Standard configuration |
|
Screen |
|
Display Type | 8″ color TFT LCD |
Resolution | 800×600 pixels |
Waveforms | Up to 7 |
ECG |
|
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *1.2 |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate range | 15-30bpm |
Calibration | ±1mv |
Accuracy | ±1bpm or ±1% (select the bigger data) |
NIBP |
|
Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
SPO2 |
|
Display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±3% (between 70%-100%) |
Pulse rate range | 20-300bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) |
|
Number of channels | 2 channels |
Measurement range | 0-50℃ |
Accuracy | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) |
|
Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
Optional configuration |
|
EtCO2-Plug & Play |
|
Measurement type | Side stream |
Measurement range | 0-10.0%; 0-76mmHg |
Accuracy | <5.0%, ±0.28kPa; ±2mmHg |
>5.0%, ±10% | |
2-IBP (optional) |
|
Measurement range | 10~300mmHg |
Number of channels | 1 or 2 channels |
Accuracy | ±1mmHg or ±2%, select bigger data |
Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
12 leads ECG (optional) |
|
Input | 3/5/10 wires ECG cable |
Lead section | I, II, III aVR, aVL, aVF, V(V1-V6) |
Heart rate range | 15-380bpm |
Calibration | ±1mv |
Product detail pictures:
Related Product Guide:
We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for 2018 China New Design Standard Model Patient Monitor - AURORA-8S 8.4 inch semi-modular ambulance patient monitor optional for ambulance – Merry, The product will supply to all over the world, such as: Bolivia, United States, Swansea, With the highest standards of product quality and service, our products have been exported to more than 25 countries like the USA, CANADA, GERMANY, FRANCE, UAE, Malaysia and so on.We are very pleased to serve customers from all over the world!