China Cheap price Neonate Patient Monitor - Aurora-8 8.4 inch multi parameter patient monitor for ambulance and transport – Merry
China Cheap price Neonate Patient Monitor - Aurora-8 8.4 inch multi parameter patient monitor for ambulance and transport – Merry Detail:
Aurora-8 8.4-inch multi parameter patient monitor for ambulance and transport
Patient monitor
Product Detail:
◆Indication of incorrect manipulation and malfunction analysis
◆Patient info input management function
◆Multi-lead ECG waveforms display in phase
◆Large volume of tabular and graphic trends information storage and easy to recall
◆Capture dynamic waveforms
◆Up to 5 hours working capacity of built-in rechargeable lithium battery
◆Unique accessory management cabinet
Networking capacity
◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Accessories:
Technique Parameter
Standard configuration |
|
Screen |
|
Display Type | 8″ color TFT LCD |
Resolution | 800×600 pixels |
Waveforms | Up to 7 |
ECG |
|
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *1.2 |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate range | 15-30bpm |
Calibration | ±1mv |
Accuracy | ±1bpm or ±1% (select the bigger data) |
NIBP |
|
Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
SPO2 |
|
Display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±3% (between 70%-100%) |
Pulse rate range | 20-300bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) |
|
Number of channels | 2 channels |
Measurement range | 0-50℃ |
Accuracy | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) |
|
Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
Optional configuration |
|
EtCO2-Plug & Play |
|
Measurement type | Side stream |
Measurement range | 0-10.0%; 0-76mmHg |
Accuracy | <5.0%, ±0.28kPa; ±2mmHg |
>5.0%, ±10% | |
2-IBP (optional) |
|
Measurement range | 10~300mmHg |
Number of channels | 1 or 2 channels |
Accuracy | ±1mmHg or ±2%, select bigger data |
Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
12 leads ECG (optional) |
|
Input | 3/5/10 wires ECG cable |
Lead section | I, II, III aVR, aVL, aVF, V(V1-V6) |
Heart rate range | 15-380bpm |
Calibration | ±1mv |
Product detail pictures:
Related Product Guide:
Our corporation puts emphasis about the administration, the introduction of talented staff, plus the construction of team building, attempting hard to improve the quality and liability consciousness of team members. Our organization successfully attained IS9001 Certification and European CE Certification of China Cheap price Neonate Patient Monitor - Aurora-8 8.4 inch multi parameter patient monitor for ambulance and transport – Merry, The product will supply to all over the world, such as: Myanmar, Ethiopia, Manchester, We welcome you to visit our company & factory and our showroom displays various products and solutions that will meet your expectations. Meanwhile, it is convenient to visit our website. Our sales staff will try their best to supply you with the best services. If you will need more information, please do not hesitate to contact us via E-mail, fax or telephone.